{"id":2029,"date":"2023-12-08T10:48:43","date_gmt":"2023-12-08T09:48:43","guid":{"rendered":"http:\/\/migration.optimed.com\/?post_type=product&#038;p=2029"},"modified":"2026-10-06T11:20:27","modified_gmt":"2026-10-06T09:20:27","slug":"CO%e2%82%82-Angioset","status":"publish","type":"product","link":"http:\/\/optimed.com\/de\/product\/CO%e2%82%82-Angioset\/","title":{"rendered":"CO\u2082-Angioset"},"content":{"rendered":"","protected":false},"featured_media":2031,"template":"","meta":{"_acf_changed":true},"product_category":[17],"class_list":["post-2029","product","type-product","status-publish","has-post-thumbnail","hentry","product_category-special-products"],"acf":{"sub_title":"ALTERNATIVE CONTRAST MEDIUM SYSTEM FOR IMAGING THE ARTERIAL AND VENOUS VESSELS","accent_color":"#668992","features":"<ul role=\"list\">\r\n \t<li>Setting of the desired gas volume, adapted to the respective region of examination<\/li>\r\n \t<li>Battery and power independent<\/li>\r\n<\/ul>","icons":"","description":"The CO\u2082-Angioset is a sterile disposable product for arterial and venous vascular imaging. Medical grade carbon dioxide with a purity \u2265 99.55 vol. % is used as the contrast medium.\r\n\r\nEspecially in patients with renal insufficiency who are intolerant to iodine-containing CM, the CO\u2082 -Angioset is recommended as a valuable alternative.\u00b9\u2019\u00b3 The CO\u2082 -Angioset is characterised by its good imaging quality and provides reliable diagnoses, especially in small vessels such as the infrapopliteal segment.\u00b3\r\n\r\nFor the use of the Angioset, a pressure reduction valve from Gloor Medical is required, which is offered in 2 versions:\r\n\r\nVersion 1: Pressure reduction valve for the gas cylinder connection\r\n\r\nVersion 2: Pressure reduction valve for the hospital CO\u2082 wall connection","details":"<h3>BENEFITS OF CO<sub>2<\/sub> ANGIOGRAPHY<\/h3>\r\nTHE ONLY 100% BIOCOMPATIBLE CONTRAST AGENT AND THE ALTERNATIVE TO CONVENTIONAL IDOINATED CONTRAST ANGIOGRAPHY\r\n<ul>\r\n \t<li>No adverse reactions such as allergy, nephrotoxicity and hepatoxicity<\/li>\r\n \t<li>Can be used for patients with an intolerance to iodinated contrast medium<\/li>\r\n \t<li>Can be used in combination with iodinated contrast agenst (to reduce side effects of non-ionic contrast agents containing iodine)<\/li>\r\n \t<li>Only small-calibre accesses are required (20G, 3F)<\/li>\r\n<\/ul>\r\n&nbsp;\r\n<h3>GENERAL COMPARISON: CO<sub>2<\/sub> VERSUS (IODINATED) CONTRAST AGENTS:<\/h3>\r\n&nbsp;\r\n<table class=\"angioset-table\">\r\n<thead>\r\n<tr>\r\n<th>Physics<\/th>\r\n<th>Contrast agent<\/th>\r\n<th>CO<sub>2<\/sub><\/th>\r\n<\/tr>\r\n<\/thead>\r\n<tbody>\r\n<tr>\r\n<td>Viscosity<\/td>\r\n<td>+<\/td>\r\n<td>-<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Flow rate<\/td>\r\n<td>-<\/td>\r\n<td>+<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Radiopacity<\/td>\r\n<td>Positive contrast agent<\/td>\r\n<td>Negative contrast agent<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Molecular structure (complexity)<\/td>\r\n<td>High<\/td>\r\n<td>Low<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Degradation \/ excretion<\/td>\r\n<td>Kidneys<\/td>\r\n<td>Lungs (primarily)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Contraindication<\/td>\r\n<td>\r\n<ul>\r\n \t<li>Contrast agent allergy<\/li>\r\n \t<li>Renal insufficiency<\/li>\r\n \t<li>Hyper \/ hypothyroidism<\/li>\r\n<\/ul>\r\n<\/td>\r\n<td>\r\n<ul>\r\n \t<li>Atrial septal defect<\/li>\r\n \t<li>Ventricular septal defect<\/li>\r\n \t<li>Open foramen ovale<\/li>\r\n \t<li>Respiratory insufficienc<\/li>\r\n \t<li>Blood vessels above the thoracolumbar junction<\/li>\r\n<\/ul>\r\n<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Binding capacity of erythrocytes<\/td>\r\n<td><\/td>\r\n<td>CO<sub>2<\/sub> (high) vs O<sub>2<\/sub> (low)<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Henderson-Hasselbach equation<\/td>\r\n<td><\/td>\r\n<td>Blood pH deviation with possible changes in the acid-base balance<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\nThis comparison represents only a general overview and does not clain to be exhaustive.\r\n\r\nFor further information, especially about contraindications, please refer to the instructions for use.\r\n<div class=\"notice\">This information does not replace the instructions for use - information for medical experts only<\/div>\r\n&nbsp;\r\n<h3>CO<sub>2<\/sub> ANGIOGRAPHY IN PRACTICE - A RELIABLE ALTERNATIVE<\/h3>\r\nFOR A BROAD RANGE OF INTERVENTIONS AND APPLICATIONS - ALSO FOR THE MORE CHALLENGING PATIENTS\r\n<div class=\"two-col\">\r\n<ul>\r\n \t<li>Renal insufficiency<\/li>\r\n \t<li>Patients with intolerance to iodinated contrast media<\/li>\r\n \t<li>Presentations of pathological shunts<\/li>\r\n \t<li>Search for sources of haemorrhage<\/li>\r\n \t<li>Display of abdominal aortic aneurysms<\/li>\r\n \t<li>Hyperthyroidisms<\/li>\r\n \t<li>Arteries of the leg<\/li>\r\n<\/ul>\r\n<ul>\r\n \t<li>Pelvic arteries<\/li>\r\n \t<li>Infrarenal aorta<\/li>\r\n \t<li>Visceral arteries<\/li>\r\n \t<li>Renal arteries<\/li>\r\n \t<li>Hemodialysis shunts<\/li>\r\n \t<li>Venous presentation<span class=\"sub-note\">(max. 40 ml pre injection)<\/span><\/li>\r\n \t<li>Cholangiography<span class=\"sub-note\">(depending on the position)<\/span><\/li>\r\n<\/ul>\r\n<\/div>","studies":"","sources":"<ul role=\"list\">\r\n \t<li>\u00b9 S3-Leitlinie zur Diagnostik, Therapie und Nachsorge der peripheren arteriellen Verschlusskrankheit 2015<\/li>\r\n \t<li>\u00b2 Radeleff B.: Angiofibel Interventionelle angiographische Diagnostik und Therapie, 2. Auflage Springer 2021<\/li>\r\n \t<li>\u00b3 Abdulghaffar W.: Role of carbon dioxide angiography in management of below knee arterial lesions, 2012<\/li>\r\n \t<li>\u2074 Teichgr\u00e4ber et al.: Periphere arterielle Interventionen, Springer 2018<\/li>\r\n \t<li>*Im Vergleich zu anderen CO\u2082-Systemen<\/li>\r\n<\/ul>","order_codes":"<h5>CO\u2082-Angioset<\/h5>\r\n<div class=\"table-wrapper\">\r\n<div class=\"table-line\">\r\n<div class=\"table-element is--two-column\">\r\n<div class=\"table-text-head is--headline is--no_rotation\">Order code<\/div>\r\n<\/div>\r\n<div class=\"table-element is--last is--two-column\">\r\n<div class=\"table-text-head is--headline is--no_rotation\">DESCRIPTION<\/div>\r\n<\/div>\r\n<\/div>\r\n<div class=\"table-line\">\r\n<div class=\"table-element is--two-column\">\r\n<div class=\"table-text\">2100-0000<\/div>\r\n<\/div>\r\n<div class=\"table-element is--last is--two-column\">\r\n<div class=\"table-text-translate\">CO\u2082-Angioset<\/div>\r\n<\/div>\r\n<\/div>\r\n<\/div>","bottom_icons":"","brochure_link_en":"https:\/\/optimed.com\/download\/4074\/?tmstv=1791278407","brochure_link_de":"","case_report_link":"","clinical_trial_link":"","datasheet_link":"","bottom_background_image":2030,"product_photos":[2553,2554,2555,2556,2557,2558,2559],"quote":"VALUABLE ALTERNATIVE TO IODINATED CONTRAST MEDIUM.","quotation_mark":"","order_codes_pdf":"","category_color":""},"_links":{"self":[{"href":"http:\/\/optimed.com\/de\/wp-json\/wp\/v2\/product\/2029","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/optimed.com\/de\/wp-json\/wp\/v2\/product"}],"about":[{"href":"http:\/\/optimed.com\/de\/wp-json\/wp\/v2\/types\/product"}],"acf:attachment":[{"embeddable":true,"href":"http:\/\/optimed.com\/de\/wp-json\/wp\/v2\/media\/2559"},{"embeddable":true,"href":"http:\/\/optimed.com\/de\/wp-json\/wp\/v2\/media\/2558"},{"embeddable":true,"href":"http:\/\/optimed.com\/de\/wp-json\/wp\/v2\/media\/2557"},{"embeddable":true,"href":"http:\/\/optimed.com\/de\/wp-json\/wp\/v2\/media\/2556"},{"embeddable":true,"href":"http:\/\/optimed.com\/de\/wp-json\/wp\/v2\/media\/2555"},{"embeddable":true,"href":"http:\/\/optimed.com\/de\/wp-json\/wp\/v2\/media\/2554"},{"embeddable":true,"href":"http:\/\/optimed.com\/de\/wp-json\/wp\/v2\/media\/2553"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/optimed.com\/de\/wp-json\/wp\/v2\/media\/2031"}],"wp:attachment":[{"href":"http:\/\/optimed.com\/de\/wp-json\/wp\/v2\/media?parent=2029"}],"wp:term":[{"taxonomy":"product_category","embeddable":true,"href":"http:\/\/optimed.com\/de\/wp-json\/wp\/v2\/product_category?post=2029"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}